ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯑꯦꯅꯔꯖꯤ-ꯏꯐꯤꯁꯤꯑꯦꯟꯇ ꯑꯣꯏꯕꯥ HVAC ꯍꯥꯌꯕꯁꯤ ꯀꯔꯤꯅꯣ?

Jan 29, 2026 ꯄꯥꯎꯖꯦꯜ ꯑꯃꯥ ꯊꯥꯗꯣꯀꯎ

I. ꯀꯣꯔ ꯑꯦꯅꯔꯖꯤꯒꯤ ꯃꯈꯂꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀꯥꯟꯅꯕꯁꯤꯡ-ꯑꯩꯆ.ꯚꯤ.ꯑꯦ.ꯁꯤ

 

ꯖꯤꯑꯣꯊꯔꯃꯦꯜ ꯍꯤꯠ ꯄꯝꯄ ꯁꯤꯁ꯭ꯇꯦꯝ ꯱

- ꯏꯅꯔꯖꯤ-ꯁꯦꯚꯤꯡ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ:ꯑꯋꯥꯡꯕꯥ ꯑꯟꯗꯔꯒ꯭ꯔꯥꯎꯟꯗ ꯂꯦꯌꯔꯁꯤꯡꯒꯤ ꯂꯦꯡꯗꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ (ꯃꯍꯧꯁꯥꯅꯥ ꯗꯤꯒ꯭ꯔꯤ 16-18 ) ꯑꯁꯤ ꯍꯤꯠ ꯁꯣꯔꯁ ꯑꯃꯁꯨꯡ ꯀꯣꯜꯗ ꯁꯣꯔꯁ ꯑꯃꯥ ꯑꯣꯏꯅꯥ ꯁꯤꯖꯤꯟꯅꯗꯨꯅꯥ, ꯃꯄꯥꯅꯒꯤ ꯑꯀꯣꯌꯔꯣꯅꯒꯤ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯗꯥ ꯑꯍꯣꯡꯕꯥ ꯂꯥꯀꯄꯗꯥ ꯊꯥꯖꯕꯥ ꯊꯃꯗꯅꯥ, ꯔꯤꯚꯔꯁ ꯀꯥꯔꯅꯣꯠ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ ꯏꯅꯗꯨꯅꯥ ꯑꯦꯅꯔꯖꯤ ꯀꯟꯕꯔꯁꯟ ꯇꯧꯕꯥ ꯉꯝꯃꯤ꯫

- ꯑꯦꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯗꯦꯇꯥ:ꯑꯦꯅꯔꯖꯤ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯔꯦꯁꯤꯑꯣ (COP) ꯑꯁꯤ 3-6 ꯐꯥꯎꯕꯥ ꯌꯧꯕꯥ ꯉꯝꯃꯤ, ꯃꯁꯤꯅꯥ ꯇꯥꯀꯄꯗꯤ ꯃꯩ 1kW ꯁꯤꯖꯤꯟꯅꯕꯅꯥ 3-6kWꯒꯤ ꯀꯨꯂꯤꯡ ꯅꯠꯠꯔꯒꯥ ꯍꯤꯇꯤꯡ ꯐꯪꯍꯅꯕꯥ ꯉꯝꯃꯤ, ꯃꯁꯤꯅꯥ ꯇ꯭ꯔꯦꯗꯤꯁꯅꯦꯜ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯗꯒꯤ 25%-50% ꯍꯦꯟꯅꯥ ꯑꯦꯅꯔꯖꯤ ꯀꯅꯕꯥ ꯉꯝꯃꯤ꯫ ꯑꯌꯨꯛ-ꯅꯨꯡꯊꯤꯂꯗꯥ, ꯃꯁꯤꯅꯥ ꯑꯆꯝꯕꯥ ꯁꯦꯟꯠꯔꯦꯜ ꯑꯦꯌꯔ ꯀꯟꯗꯤꯁꯅꯗꯒꯤ 30%-40% ꯍꯦꯟꯅꯥ ꯑꯦꯅꯔꯖꯤ ꯀꯅꯕꯥ ꯉꯝꯃꯤ, ꯑꯃꯁꯨꯡ ꯅꯣꯡꯖꯨ ꯃꯇꯃꯗꯥ, ꯃꯁꯤꯅꯥ ꯅꯨꯡꯁꯤꯠ ꯁꯦꯡꯍꯟꯅꯕꯒꯤꯗꯃꯛ ꯒ꯭ꯌꯥꯁ ꯕꯣꯏꯂꯔꯁꯤꯡꯗꯒꯤ 40%-50% ꯍꯦꯟꯅꯥ ꯑꯦꯅꯔꯖꯤ ꯀꯅꯕꯥ ꯉꯝꯃꯤ꯫

- ꯑꯍꯦꯅꯕꯥ ꯀꯥꯟꯅꯕꯁꯤꯡ:ꯂꯣꯡ ꯂꯥꯏꯐꯁ꯭ꯄꯦꯟ (ꯏꯟꯗꯣꯔ ꯀꯝꯄꯣꯅꯦꯟꯇꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯥ ꯆꯍꯤ 20-25, ꯑꯟꯗꯔꯒ꯭ꯔꯥꯎꯟꯗ ꯄꯥꯏꯄꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯥ ꯆꯍꯤ 50ꯒꯤ ꯃꯊꯛꯇꯥ), ꯁ꯭ꯇꯦꯕꯜ ꯑꯣꯄꯔꯦꯁꯟ, ꯍꯧꯖꯤꯀꯁꯨ ꯑꯀꯅꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯑꯀꯣꯌꯔꯣꯅꯁꯤꯡꯗꯥ (-15 ꯗꯤꯒ꯭ꯔꯤ ꯂꯣ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ/38 ꯗꯤꯒ꯭ꯔꯤ ꯍꯥꯏ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ) ꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯊꯕꯛ ꯇꯧꯕꯥ ꯉꯝꯃꯤ, ꯑꯃꯁꯨꯡ ꯃꯇꯝ ꯑꯃꯠꯇꯗꯥ ꯀꯨꯂꯤꯡ, ꯍꯤꯇꯤꯡ ꯑꯃꯁꯨꯡ ꯗꯣꯃꯦꯁ꯭ꯇꯤꯛ ꯍꯣꯠ ꯋꯥꯇꯔ ꯄꯤꯕꯥ ꯉꯝꯃꯤ, ꯃꯁꯤꯅꯥ ꯃꯜꯇꯤ-ꯐꯉ꯭ꯀꯁꯅꯦꯜ ꯌꯨꯅꯤꯠ ꯑꯃꯥ ꯑꯣꯏꯍꯜꯂꯤ꯫

74e5938e90b72edc773006c7a145ba5etplv-be4g95zd3a-image
3eb38cf864b2e9f82cb8034bce5a8d12tplv-be4g95zd3a-image

2. ꯚꯦꯔꯤꯑꯦꯕꯜ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯐ꯭ꯂꯣ (ꯚꯤ.ꯑꯥꯔ.ꯑꯦꯐ.) ꯁꯤꯁ꯭ꯇꯦꯝ꯫

- ꯑꯦꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯇꯧꯕꯒꯤ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ: ꯚꯦꯔꯤꯑꯦꯕꯜ ꯐ꯭ꯔꯤꯛꯕꯦꯟꯁꯤ ꯀꯝꯞꯔꯦꯁꯔ ꯑꯁꯤ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯐ꯭ꯂꯣ ꯑꯁꯤ ꯑꯀꯛꯅꯅꯥ ꯔꯤꯒꯨꯂꯦꯠ ꯇꯧꯕꯗꯥ ꯁꯤꯖꯤꯟꯅꯩ, ꯃꯁꯤꯅꯥ ꯇꯣꯉꯥꯟ ꯇꯣꯉꯥꯅꯕꯥ ꯃꯐꯃꯁꯤꯡꯗꯥ ꯃꯇꯝ ꯑꯃꯗꯥ ꯀꯨꯂꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯤꯇꯤꯡ ꯇꯧꯕꯥ ꯉꯃꯍꯜꯂꯤ ꯑꯃꯁꯨꯡ ꯏꯅꯔꯖꯤ ꯃꯥꯡꯍꯅꯕꯥ ꯉꯃꯍꯜꯂꯤ꯫

- ꯑꯦꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯗꯦꯇꯥ:ꯀꯨꯂꯤꯡ ꯏꯅꯔꯖꯤ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯔꯦꯁꯤꯑꯣ (SEER) ꯑꯁꯤ 42 ꯐꯥꯎꯕꯥ ꯌꯧꯕꯥ ꯉꯝꯃꯤ, ꯃꯁꯤꯅꯥ ꯑꯆꯝꯕꯥ ꯑꯦꯌꯔ ꯀꯟꯗꯤꯁꯟ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯍꯦꯜꯂꯤ꯫ ꯃꯁꯤꯅꯥ ꯔꯤꯖꯅꯦꯜ ꯂꯣꯗꯀꯤ ꯃꯇꯨꯡ ꯏꯟꯅꯥ ꯑꯣꯄꯔꯦꯇꯤꯡ ꯄꯥꯋꯔ ꯑꯗꯨ ꯗꯥꯏꯅꯥꯃꯤꯛ ꯑꯣꯏꯅꯥ ꯑꯦꯗꯖꯁ꯭ꯠ ꯇꯧꯕꯥ ꯉꯝꯃꯤ, ꯃꯁꯤꯅꯥ ꯑꯆꯧꯕꯥ ꯂꯣꯗ ꯐ꯭ꯂꯨꯛꯇꯦꯁꯟ ꯂꯩꯕꯥ ꯁꯤꯅꯥꯔꯤꯑꯣꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯅꯕꯥ ꯑꯣꯏꯍꯜꯂꯤ꯫

- ꯑꯍꯦꯅꯕꯥ ꯀꯥꯟꯅꯕꯁꯤꯡ:ꯑꯋꯥꯡꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ ꯀꯟꯠꯔꯣꯜ ꯑꯦꯛꯌꯨꯔꯦꯁꯤ, ꯐ꯭ꯂꯦꯛꯁꯤꯕꯜ ꯖꯣꯅꯤꯡ, ꯈꯨꯗꯣꯡꯆꯥꯕꯥ ꯏꯅꯁ꯭ꯇꯣꯂꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯃꯦꯟꯇꯤꯅꯦꯟꯁ, ꯀꯝꯃꯔꯁꯤꯑꯦꯜ ꯕꯤꯜꯗꯤꯡꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯣꯐꯤꯁ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯒꯨꯝꯕꯥ ꯃꯐꯝ ꯀꯌꯥꯗꯥ ꯆꯨꯅꯕꯥ꯫

3. ꯗꯛꯇꯂꯦꯁ ꯃꯤꯅꯤ-ꯁ꯭ꯞꯂꯤꯠ ꯍꯤꯠ ꯄꯝꯄꯁꯤꯡ꯫

- ꯏꯅꯔꯖꯤ-ꯁꯦꯚꯤꯡ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ:ꯑꯦꯌꯔ ꯇ꯭ꯔꯥꯟꯁꯄꯣꯔꯠ ꯇꯧꯕꯗꯥ ꯑꯦꯌꯔ ꯗꯛꯇ ꯑꯃꯠꯇꯥ ꯃꯊꯧ ꯇꯥꯗꯦ, ꯃꯁꯤꯅꯥ ꯑꯦꯌꯔ ꯗꯛꯇꯀꯤ ꯍꯤꯠ ꯂꯣꯁ (traditional air duct loss) ꯑꯁꯤ 20%-30% ꯑꯣꯏꯍꯜꯂꯤ, ꯑꯃꯁꯨꯡ ꯃꯐꯝ ꯑꯃꯈꯛꯇꯗꯥ ꯃꯅꯤꯡꯇꯝꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ ꯀꯟꯠꯔꯣꯜ ꯇꯧꯕꯥ ꯉꯃꯍꯜꯂꯤ꯫

- ꯑꯦꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯗꯦꯇꯥ:ꯑꯦꯁ.ꯏ.ꯏ.ꯑꯥꯔ.ꯒꯤ ꯚꯦꯜꯌꯨ ꯑꯁꯤ ꯳꯸ ꯐꯥꯑꯣꯕꯥ ꯌꯧꯕꯥ ꯌꯥꯏ, ꯃꯁꯤꯅꯥ ꯗꯛꯇꯋꯔꯛ ꯃꯣꯗꯤꯐꯤꯀꯦꯁꯟ ꯌꯥꯑꯣꯗꯅꯥ ꯑꯄꯤꯀꯄꯥ ꯃꯐꯃꯁꯤꯡ ꯅꯠꯠꯔꯒꯥ ꯁꯤꯅꯥꯔꯤꯑꯣꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯅꯕꯥ ꯑꯣꯏꯍꯜꯂꯤ꯫ ꯃꯁꯤꯒꯤ ꯏꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯏꯐꯦꯛꯇ ꯑꯁꯤ ꯇ꯭ꯔꯦꯗꯤꯁꯅꯦꯜ ꯁ꯭ꯞꯂꯤꯠ ꯑꯦꯌꯔ ꯀꯟꯗꯤꯁꯅꯔꯁꯤꯡꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯍꯦꯟꯅꯥ ꯐꯩ꯫

- ꯑꯍꯦꯅꯕꯥ ꯀꯥꯟꯅꯕꯁꯤꯡ:ꯐ꯭ꯂꯦꯛꯁꯤꯕꯜ ꯏꯅꯁ꯭ꯇꯣꯂꯦꯁꯟ, ꯑꯇꯦꯅꯕꯥ ꯀꯟꯁꯠꯔꯛꯁꯅꯒꯤ ꯃꯇꯝ, ꯑꯔꯤꯕꯥ ꯕꯤꯜꯗꯤꯡ ꯔꯤꯅꯣꯕꯦꯁꯟ, ꯚꯤꯂꯥ, ꯑꯄꯤꯀꯄꯥ ꯗꯨꯀꯥꯅꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄꯥ ꯁꯤꯅꯥꯔꯤꯑꯣꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯅꯕꯥ, ꯑꯃꯁꯨꯡ ꯅꯣꯡꯂꯩ-ꯅꯨꯡꯁꯤꯠ ꯅꯦꯝꯕꯥ ꯑꯃꯁꯨꯡ ꯅꯨꯡꯉꯥꯏꯕꯥ ꯌꯥꯝꯅꯥ ꯂꯩꯕꯥ꯫

8b35c6892dfec3274887c77369811c86tplv-be4g95zd3a-image
2f45b3703eb99055bf14d7c2999d8514tplv-be4g95zd3a-image

꯴.ꯀꯝꯕꯤꯅꯦꯠ ꯍꯤꯠ ꯄꯝꯄ ꯁꯤꯁ꯭ꯇꯦꯝ (ꯒ꯭ꯔꯥꯎꯟꯗ ꯁꯣꯔꯁ + ꯑꯦꯌꯔ ꯁꯣꯔꯁ) ꯴.

- ꯏꯅꯔꯖꯤ-ꯁꯦꯚꯤꯡ ꯄ꯭ꯔꯤꯟꯁꯤꯄꯜ:ꯃꯁꯤꯅꯥ ꯒ꯭ꯔꯥꯎꯟꯗ ꯁꯣꯔꯁ ꯍꯤꯠ ꯄꯝꯄꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯦꯌꯔ ꯁꯣꯔꯁ ꯍꯤꯠ ꯄꯝꯄꯁꯤꯡꯒꯤ ꯈꯨꯗꯣꯡꯆꯥꯕꯁꯤꯡ ꯄꯨꯅꯁꯤꯜꯂꯤ, ꯑꯃꯁꯨꯡ ꯏꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯦꯗꯞꯇꯦꯕꯤꯂꯤꯇꯤ ꯕꯦꯂꯦꯟꯁ ꯇꯧꯅꯕꯥ ꯀꯥꯂꯦꯟ ꯑꯃꯁꯨꯡ ꯑꯦꯝꯕꯤꯑꯦꯟꯇ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅꯥ ꯊꯕꯛ ꯇꯧꯕꯒꯤ ꯃꯑꯣꯡ ꯑꯁꯤ ꯃꯁꯥ ꯃꯊꯟꯇꯥ ꯍꯣꯡꯗꯣꯀꯏ꯫

- ꯑꯦꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯗꯦꯇꯥ: ꯇꯁꯦꯡꯕꯥ ꯃꯥꯌꯄꯥꯀꯄꯁꯤꯡꯅꯥ ꯇꯥꯛꯂꯤ ꯃꯗꯨꯗꯤ ꯀꯝꯃꯔꯁꯤꯑꯦꯜ ꯁꯤꯅꯥꯔꯤꯑꯣꯁꯤꯡꯗꯥ, ꯌꯨꯅꯤꯠ ꯑꯦꯔꯤꯌꯥ ꯑꯃꯗꯥ ꯏꯅꯔꯖꯤ ꯀꯟꯖꯨꯝꯄꯁꯟ ꯑꯁꯤ ꯇ꯭ꯔꯦꯗꯤꯁꯅꯦꯜ ꯁꯦꯟꯠꯔꯦꯜ ꯑꯦꯌꯔ ꯀꯟꯗꯤꯁꯅꯗꯒꯤ 34% ꯍꯦꯟꯅꯥ ꯍꯦꯜꯂꯤ, ꯑꯃꯁꯨꯡ ꯆꯍꯤꯒꯤ ꯑꯣꯏꯅꯥ ꯏꯅꯔꯖꯤꯒꯤ ꯃꯃꯜ ꯑꯁꯤ ꯌꯨꯌꯥꯟ 80,000 ꯍꯦꯟꯅꯥ ꯍꯟꯊꯍꯅꯕꯥ ꯌꯥꯏ (1200million ꯑꯣꯐꯤꯁ ꯕꯤꯜꯗꯤꯡ ꯑꯃꯒꯤ ꯀꯦꯁ)꯫

- ꯑꯍꯦꯅꯕꯥ ꯀꯥꯟꯅꯕꯁꯤꯡ:ꯁꯤꯅꯥꯔꯤꯑꯣ ꯄꯨꯝꯅꯃꯛꯇꯥ ꯑꯦꯗꯞꯇꯦꯕꯜ ꯑꯣꯏꯕꯥ, ꯇꯣꯉꯥꯟ-ꯇꯣꯉꯥꯅꯕꯥ ꯀ꯭ꯂꯥꯏꯃꯦꯠ ꯔꯤꯖꯅꯁꯤꯡ ꯍꯦꯟꯗꯜ ꯇꯧꯕꯥ ꯉꯝꯕꯥ, ꯑꯆꯦꯠꯄꯥ ꯑꯣꯄꯔꯦꯁꯅꯦꯜ ꯁ꯭ꯇꯦꯕꯤꯂꯤꯇꯤ ꯂꯩꯕꯥ, ꯃꯁꯤꯅꯥ ꯀꯝꯃꯔꯁꯤꯑꯦꯜ ꯕꯤꯜꯗꯤꯡꯁꯤꯡꯒꯤ ꯏꯅꯔꯖꯤ-ꯁꯦꯚꯤꯡ ꯔꯤꯅꯣꯚꯦꯁꯅꯒꯤꯗꯃꯛꯇꯥ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯄꯥꯝꯅꯕꯥ ꯁꯣꯂꯨꯁꯟ ꯑꯣꯏꯍꯜꯂꯤ꯫

II. ꯃꯔꯨꯑꯣꯏꯕꯥ ꯏꯅꯔꯖꯤ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯏꯟꯗꯤꯀꯦꯇꯔꯁꯤꯡ ꯁꯟꯗꯣꯛꯅꯥ ꯇꯥꯀꯈ꯭ꯔꯦ (ꯄ꯭ꯔꯗꯛꯇ ꯈꯅꯕꯗꯥ ꯇꯉꯥꯏ ꯐꯗꯕꯥ)

 

 

prodmodular-1
ꯃꯒꯨꯟ
ꯊꯥꯛ
  • ꯑꯦꯁ.ꯏ.ꯏ.ꯑꯥꯔ.(ꯁꯤꯖꯅꯦꯜ ꯏꯅꯔꯖꯤ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯔꯦꯁꯤꯑꯣ):

    ꯀꯨꯂꯤꯡ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯃꯥꯄꯜꯂꯤ꯫ ꯚꯦꯜꯌꯨ ꯑꯗꯨ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕꯥ ꯃꯇꯃꯗꯥ, ꯃꯁꯤ ꯍꯦꯟꯅꯥ ꯑꯦꯅꯔꯖꯤ-ꯏꯐꯤꯁꯤꯑꯦꯟꯇ ꯑꯣꯏ꯫ ꯑꯔꯗꯤꯅꯥꯔꯤ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡ ꯑꯁꯤ ꯱꯶ꯇꯒꯤ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ, ꯑꯋꯥꯡꯕꯥ-ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡ ꯑꯁꯤ ꯲꯰ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ, ꯑꯃꯁꯨꯡ ꯃꯊꯛꯀꯤ-ꯂꯥꯏꯅꯒꯤ ꯄꯣꯠꯊꯣꯀꯁꯤꯡꯒꯤ -ꯂꯥꯏꯅꯥ ꯳꯸-꯴꯲ ꯌꯧꯕꯥ ꯉꯝꯃꯤ꯫

  • HSPF (ꯍꯤꯠ ꯄꯝꯄꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯥ ꯁꯤꯖꯅꯦꯜ ꯏꯅꯔꯖꯤ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯔꯦꯁꯤꯑꯣ):

    ꯍꯤꯇꯤꯡ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯃꯥꯄꯜꯂꯤ꯫ ꯚꯦꯜꯌꯨ ꯍꯦꯟꯅꯥ ꯋꯥꯡꯕꯥ ꯃꯇꯃꯗꯥ, ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯗꯨ ꯍꯦꯟꯅꯥ ꯏꯅꯔꯖꯤ-ꯏꯐꯤꯁꯤꯑꯦꯟꯇ ꯑꯣꯏ꯫ ꯑꯆꯝꯕꯥ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯗꯤ, ꯃꯁꯤ 8ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ ꯑꯣꯏ, ꯑꯃꯁꯨꯡ ꯑꯋꯥꯡꯕꯥ-ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯗꯤ, ꯃꯁꯤ 10ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯆꯥꯎꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯥꯟꯅꯕꯥ ꯑꯣꯏ꯫

  • ꯁꯤ.ꯑꯣ.ꯄꯤ.(ꯀꯣꯑꯣꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯑꯣꯐ ꯄꯔꯐꯣꯃꯦꯟꯁ): .

    ꯑꯄꯨꯅꯕꯥ ꯏꯅꯔꯖꯤ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯏꯟꯗꯦꯛꯁ꯫ ꯒ꯭ꯔꯥꯎꯟꯗ ꯁꯣꯔꯁ ꯍꯤꯠ ꯄꯝꯄꯁꯤꯡꯗꯥ ꯃꯍꯧꯁꯥꯅꯥ COP 3-6 ꯂꯩ, ꯃꯁꯤꯅꯥ ꯇ꯭ꯔꯦꯗꯤꯁꯅꯦꯜ ꯑꯦꯌꯔ ꯀꯟꯗꯤꯁꯅꯔꯁꯤꯡ (COP ꯆꯥꯎꯔꯥꯛꯅꯥ 1.5-2.5)ꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯍꯦꯜꯂꯤ꯫

  • ꯑꯦ.ꯑꯦꯐ.ꯌꯨ.ꯏ.(ꯆꯍꯤꯒꯤ ꯑꯣꯏꯅꯥ ꯐ꯭ꯌꯨꯑꯦꯜ ꯌꯨꯇꯤꯂꯥꯏꯖꯦꯁꯟ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ)

    ꯐ꯭ꯌꯨꯑꯦꯜ/ꯒꯦꯁ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯗꯤ, ꯃꯁꯤꯅꯥ ꯐ꯭ꯌꯨꯑꯦꯜ ꯌꯨꯇꯤꯂꯥꯏꯖꯦꯁꯟ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯂꯦꯄꯊꯣꯀꯏ; ꯍꯥꯏ-ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯗꯥ ꯌꯨꯇꯤꯂꯥꯏꯖꯦꯁꯅꯒꯤ ꯆꯥꯡ ꯑꯁꯤ 98%ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯅꯠꯠꯔꯒꯥ ꯃꯁꯤꯒꯥ ꯃꯥꯟꯅꯩ꯫

 

ꯑꯅꯌꯥꯡ ꯇꯦꯡꯒ꯭ꯔꯨꯏ ꯏꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯏꯛꯕꯤꯄꯃꯦꯟꯇ ꯀꯣꯡ, ꯂꯤꯃꯤꯇꯦꯗꯅꯥ ꯌꯨ.ꯑꯦꯁ.

ꯀꯔꯤꯒꯨꯝꯕꯥ ꯅꯍꯥꯛꯅꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖꯔ ꯌꯨꯅꯤꯇꯁꯤꯡꯒꯤ ꯃꯇꯥꯡꯗꯥ ꯍꯦꯟꯅꯥ ꯈꯪꯅꯤꯡꯂꯕꯗꯤ ꯅꯠꯠꯔꯒꯥ ꯌꯣꯅꯕꯥ ꯄꯥꯝꯂꯕꯗꯤ, ꯆꯥꯅꯕꯤꯗꯨꯅꯥ ꯏꯃꯦꯏꯜ ꯑꯃꯥ ꯊꯥꯕꯤꯌꯨ꯫꯹꯹꯸꯸xiaoshuai@gmail.com, ꯑꯩꯈꯣꯌꯅꯥ ꯄꯥꯎꯖꯦꯜ ꯑꯁꯤ ꯎꯔꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯃꯇꯝ ꯆꯥꯅꯥ ꯄꯥꯎꯈꯨꯝ ꯄꯤꯒꯅꯤ!

ꯄ꯭ꯔꯣꯐꯦꯁ꯭ꯅꯦꯜ ꯇꯤꯝ꯫

ꯑꯩꯈꯣꯌꯒꯤ ꯀꯝꯄꯦꯅꯤ ꯑꯁꯤ ꯀꯣꯔ ꯑꯣꯏꯅꯥ ꯇꯦꯛꯅꯤꯀꯦꯜ ꯄꯔꯁꯣꯅꯦꯂꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯑꯋꯥꯡꯕꯥ-ꯀ꯭ꯕꯥꯂꯤꯇꯤꯒꯤ ꯑꯥꯐꯇꯔ-ꯁꯦꯂꯁ ꯁꯔꯚꯤꯁ ꯇꯤꯝ ꯑꯃꯥ ꯌꯥꯑꯣꯔꯤ, ꯑꯃꯁꯨꯡ ꯌꯨꯖꯔꯁꯤꯡꯗꯒꯤ ꯁꯔꯚꯤꯁ ꯏꯅꯐꯣꯔꯃꯦꯁꯟ ꯅꯣꯇꯤꯐꯤꯀꯦꯁꯅꯁꯤꯡ ꯐꯪꯂꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯃꯇꯝ ꯆꯥꯅꯥ ꯐꯤꯗꯕꯦꯛ ꯄꯤꯒꯅꯤ꯫

ꯄꯨꯡ ꯷x꯲꯴ꯗꯥ ꯌꯧꯍꯅꯕꯥ꯫

ꯑꯩꯈꯣꯌꯒꯤ ꯀꯝꯄꯦꯅꯤ ꯑꯁꯤꯅꯥ ꯑꯩꯈꯣꯌꯅꯥ ꯌꯣꯜꯂꯤꯕꯥ ꯄꯣꯠꯊꯣꯀꯁꯤꯡꯒꯤꯗꯃꯛ ꯐ꯭ꯔꯤ ꯇꯦꯛꯅꯤꯀꯦꯜ ꯁꯄꯣꯔꯠ ꯄꯤꯔꯤ ꯑꯃꯁꯨꯡ ꯃꯔꯤ ꯂꯩꯅꯕꯥ ꯄꯔꯁꯣꯅꯦꯂꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯇꯦꯛꯅꯤꯀꯦꯜ ꯇ꯭ꯔꯦꯅꯤꯡ ꯑꯣꯔꯒꯅꯥꯏꯖ ꯇꯧꯔꯤ꯫

back
 

ꯍꯧꯖꯤꯛ ꯀꯟꯇꯦꯛꯇ ꯇꯧꯕꯤꯌꯨ꯫